In many cases in lab is uncertain of wavelengths better for their application, ATR3200 dual-band Raman spectrometer integrate two wavelengths laser sources to detect small sample. It requires no contact, no treatment to make an undestructive detect. This instrument has advantages of high performance-to-ratio, smart size can detect liquids, including fabrics, biology, alcoholics, crystals etc.
ATR3200 built-in 532nm, 633nm, 785nm Raman spectrometers, all of them employs cooled high sensitivity Raman signal enhanced CCD, high efficient Raman probe with a laser power up to 600mW narrow linewidth lasers, combined with high reliable optical design, circuit design, structure design, detect result is very stable, and super SNR.
ATR3200 built in 1064 Raman, employs ultra high cooled semi-conductor lasers, 2nd class cooled ultra high sensitivity InGaAs linear array CCD. As a result, with high performance, high sensitivity can fit to scientific research, medical instrument industry.
ATR3200-785+1064 |
785+1064 |
500 |
200 ~ 3500 |
3 ~ 8 |
500 |
200 ~ 2600 |
7 ~ 12 |
ATR3200-532+633 |
532+633 |
100 |
200 ~ 3700 |
5 ~ 7 |
50 |
200 ~ 3500 |
3 ~ 6 |
ATR3200-532+1064 |
532+1064 |
100 |
200 ~ 3700 |
5 ~ 7 |
500 |
200 ~ 2600 |
7 ~ 12 |
ATR3200-532+785 |
532+785 |
100 |
200 ~ 3700 |
5 ~ 7 |
500 |
200 ~ 3500 |
3 ~ 8 |
ATR3200-633+1064 |
633+1064 |
50 |
200 ~ 3500 |
3 ~ 6 |
500 |
200 ~ 2600 |
7 ~ 12 |
Specification
EXCITATION LIGHT |
Power Stability |
σ/μ <±0.2% |
DETECTOR |
Cooled Down To |
-10 ℃ |
Detector Type |
785:200-1100 nm 1064: 900-1700 nm |
Detector Model |
785:High sensitivity Cooled CCD 1064:High sensitivity 512 pixels InGaAs detector |
RAMAN INSTRUMENT |
Interfaces |
WIFI, 4G(optional) |
Integration Time |
4ms - 120s |
Operation System |
Android |
Excitation Wavelength |
785nm±0.5nm 1064±0.5nm |
Power Voltage |
AC 220V(+/-5%) |
Spectral Range |
785:250-2700, 200-3500, 200-4200optional 1064: 200-2600 |
SNR |
>3000:1 |
Weight |
27Kg |
Reliability |
Spectral Stability σ/μ < 0.5% (COT 8 hours) Temp Stability shift ≤ 1 cm-1 (10-40 ℃) Spectral intensity change(in 5 ~ 40 ℃) <±5% |
Size |
800*500*300mm |
Dynamic Range |
785: 50000:1 1064:80000:1 |
Interface |
USB2.0 |
OPTICAL PARAMETER |
Working Temperature |
-10~40 ℃ |
Working Humidity |
< 95% |
RAMAN PROBE |
Rayleigh Scattering Resistance |
Working Distance 6 mm OD OD>8 NA 0.3 Aperture 7mm |
Features
l Dual bands:532, 633, 785, 1064nm (optional dual wavelengths combination);
l High sensitivity, SNR>3000:1
l High Stability
l Hamamatscu CCD, excellent performance;
l High performance spectrometer
l USB2.0 connect to PC
/uploadfile/2020/0316/20200316033846571.docx