785nm Raman spectrometer Local:Home > 532nm+633nm Dual-band Portable Raman Spectrometer

532nm+633nm Dual-band Portable Raman Spectrometer

◆Specifications:

Wavelength(nm)ModelOutput power (mW)Data sheets



In many cases in lab is uncertain of wavelengths better for their application, ATR3200 dual-band Raman spectrometer integrate two wavelengths laser sources to detect small sample. It requires no contact, no treatment to make an undestructive detect. This instrument has advantages of high performance-to-ratio, smart size can detect liquids, including fabrics, biology, alcoholics, crystals etc.
ATR3200 built-in 532nm, 633nm, 785nm Raman spectrometers, all of them employs cooled high sensitivity Raman signal enhanced CCD, high efficient Raman probe with a laser power up to 600mW narrow linewidth lasers, combined with high reliable optical design, circuit design, structure design, detect result is very stable, and super SNR.
ATR3200 built in 1064 Raman, employs ultra high cooled semi-conductor lasers, 2nd class cooled ultra high sensitivity InGaAs linear array CCD. As a result, with high performance, high sensitivity can fit to scientific research, medical instrument industry.
ATR3200-785+1064 785+1064 500 200 ~ 3500 3 ~ 8
500 200 ~ 2600 7 ~ 12
ATR3200-532+633 532+633 100 200 ~ 3700 5 ~ 7
50 200 ~ 3500 3 ~ 6
ATR3200-532+1064 532+1064 100 200 ~ 3700 5 ~ 7
500 200 ~ 2600 7 ~ 12
ATR3200-532+785 532+785 100 200 ~ 3700 5 ~ 7
500 200 ~ 3500 3 ~ 8
ATR3200-633+1064 633+1064 50 200 ~ 3500 3 ~ 6
500 200 ~ 2600 7 ~ 12
 
Specification
EXCITATION LIGHT
Power Stability σ/μ <±0.2%
DETECTOR
Cooled Down To -10 ℃
Detector Type 785:200-1100 nm 1064: 900-1700 nm
Detector Model 785:High sensitivity Cooled CCD 1064:High sensitivity 512 pixels InGaAs detector
RAMAN INSTRUMENT
Interfaces WIFI, 4G(optional)
Integration Time 4ms - 120s
Operation System Android
Excitation Wavelength 785nm±0.5nm 1064±0.5nm
Power Voltage AC 220V(+/-5%)
Spectral Range 785:250-2700, 200-3500, 200-4200optional 1064: 200-2600
SNR >3000:1
Weight 27Kg
Reliability Spectral Stability σ/μ < 0.5% (COT 8 hours) Temp Stability shift ≤ 1 cm-1 (10-40 ℃) Spectral intensity change(in 5 ~ 40 ℃) <±5%
Size 800*500*300mm
Dynamic Range 785: 50000:1 1064:80000:1
Interface USB2.0
OPTICAL PARAMETER
Working Temperature -10~40 ℃
Working Humidity < 95%
RAMAN PROBE
Rayleigh Scattering Resistance Working Distance 6 mm OD OD>8 NA 0.3 Aperture 7mm
Features
l Dual bands:532, 633, 785, 1064nm (optional dual wavelengths combination);
l High sensitivity, SNR>3000:1
l High Stability
l Hamamatscu CCD, excellent performance;
l High performance spectrometer
l USB2.0 connect to PC
 