ATP5040 uses 4096pixels, other parameters almost the same as ATP5020, it employs the ultra-high performance, high-sensitivity, high-resolution, and cost-effective model. The award-winner spectrometer is called cooled Maya, it can even replace Maya and QE65 in SNR, sensitivity, and resolution. It's ideal for Raman system well. It uses, a back-thinned CCD array, TE-cooled down to -10 ℃. Sensor noise is further reduced, and SNR is almost 2 times higher than others. Increased reliability can remain measure result unchanged with temperature.
Customized design of ultra-low noise CCD signal processing circuit built inside, Noise is lower can 3 counts is ahead of records in the industries.
ATP5040 is designed with SMA905 optic fiber entrance connector or free space, and it outputs spectral data via USB2.0/UART
DETECTOR |
Detector Type |
Back-thinned Linear array detector, TE-cooled to -10℃ |
Spectral Range |
193-1008nm |
Effective Pixels |
4096pixels |
Pixels Dimension |
7x200 um |
Full Well Capacity |
NA |
Detector Model |
hamamtsu s13496 +TEC |
Sensitivity |
650 uV/e- |
Dark Noise |
0.4mVrms |
OPTICAL PARAMETER |
Wavelength Range |
193-1008nm, 200-1000 nm, 200850nm, 600-1000nm, 800-1000nm |
Optical Resolution |
5 to 200 µm |
Signal-To-Noise |
>600:1 |
Dynamic Range |
50000 |
Working Temperature |
-10°c to + 50°c |
Numberical Aperture |
0.11 |
Working Humidity |
< 90% NC |
Trigger |
YES(IN and OUT) |
Cooling Temperature |
-5°c |
Scanning Rate |
< 1 kfps |
OPTICAL CONFIGURATION |
Optical Design |
f/4 crossed asymmetrical Czerny-Turner |
Focal Distance |
40/60mm |
Incident Slit |
50 μm (5, 10, 25, 50, 100, or 200 μm optional) |
Incident Interface |
SMA905 connector,free space |
ELECTRICAL PARAMETER |
Integration Time |
1 ms - 80 s |
Interfaces |
USB 2.0 (480MHz High speed) |
A/D Conversion Resolution |
18 bit |
Supply Voltage |
DC4.5 to 5.5 V (type @5V) |
Operating Current |
<2.3A |
Storage Temperature |
-30°c to + 70 °c |
PHYSICAL PARAMETERS |
Dimension |
170×110×52 mm^3 |
Weight |
1.2kg |
Sealing |
Anit-sweat |
Feature:
Detector:back-thinned CCD, TE-cooled down to -10 ℃
CCD parameters:4096pixels, 14×14um
Ultra-low noise CCD signal processing circuit
Spectral range: 180-1180nm
Spectral resolution: 0.01-1.3nm(depend on spectral range, slit width)
Optical path:crossed Czerny-Turner (C-T)
Integration time:1ms-130s
power supply:DC 5V±10% @ <2.3A
18 bit, 570KHz A/D Converter
Entrance connector:SMA905 connector or free space
Output interface: high-speed USB2.0 or UART
20 pins, dual rows programmable extension connector